Seven Sisters, Rochdale

Comprehensive external wall intrusive survey conducted at the Seven Sisters as part of a Fire Risk Assessment of External Wall (FRAEW), ensuring fire safety compliance and resident protection.

External Wall Survey

External Wall Survey

External Wall Survey

FRAEW

FRAEW

FRAEW

Building

Seven Sisters

Location

UK, Rochdale

Requirements

Internal structural protection inspection
and compartmentation survey

Internal structural protection inspection and compartmentation survey

Internal structural protection inspection and compartmentation survey

Project Overview:

Our team conducted an external wall intrusive survey at Seven Sisters as part of a Fire Risk Assessment of External Wall (FRAEW). This comprehensive investigation was essential in assessing the building’s fire safety measures and ensuring adherence to current fire safety standards for multi-storey residential properties.

Scope of Work:

At Seven Sisters, our survey involved:

  1. External Wall Intrusive Survey:
  • Conducted a thorough inspection of the external façade, focusing on cladding, insulation, and cavity barriers.

  • Opened selected areas of the façade to verify the materials and their compatibility with fire safety requirements.

  • Investigated key wall components, including membranes, fire barriers, and external finishes.

  1. Fire Safety Compliance Assessment:
  • Assessed the condition, installation, and performance of fire-stopping measures to ensure their effectiveness.

  • Evaluated compliance with building regulations and fire safety guidelines.

  • Delivered a structured report with detailed findings to assist in any necessary remediation planning.

Objectives:

The primary objectives of the Seven Sisters survey were to:

  • Identify and evaluate the components of the external wall systems.

  • Detect any fire safety vulnerabilities or installation errors.

  • Provide actionable recommendations to improve compliance and safety.

Scope of Work:

At Seven Sisters, our survey involved:

  1. External Wall Intrusive Survey:
  • Conducted a thorough inspection of the external façade, focusing on cladding, insulation, and cavity barriers.

  • Opened selected areas of the façade to verify the materials and their compatibility with fire safety requirements.

  • Investigated key wall components, including membranes, fire barriers, and external finishes.

  1. Fire Safety Compliance Assessment:
  • Assessed the condition, installation, and performance of
    fire-stopping measures to ensure their effectiveness.

  • Evaluated compliance with building regulations and fire safety guidelines.

  • Delivered a structured report with detailed findings to assist in any necessary remediation planning.

Objectives:

The primary objectives of the Seven Sisters survey were to:

  • Identify and evaluate the components of the external wall systems.

  • Detect any fire safety vulnerabilities or installation errors.

  • Provide actionable recommendations to improve compliance
    and safety.

Key Findings:

The survey revealed critical insights into the external wall systems, identifying both strengths and areas that required remedial work. The findings highlighted the importance of regular inspections to maintain fire safety and compliance standards.

Outcome:

Our inspection provided the building management with a clear understanding of the façade’s condition and compliance status. This allowed them to make informed decisions on implementing necessary fire safety enhancements to protect residents and ensure regulatory alignment.

Need Expert Fire Safety Services?

If you’re looking for thorough structural protection inspections or compartmentation surveys, contact us today to learn how we can help safeguard your building.

Years experience

0+

Projects completed

0

Current clients

0

Surveys conducted

0+

Recent Projects

Recent Projects

An overview of our recent work, showcasing tailored fire safety solutions that ensure compliance and safety.

An overview of our recent work, showcasing tailored fire safety solutions that ensure compliance
and safety.

The Ritz London

External Wall Survey (RIBA 5)

Project

The Ritz London

The Ritz London

External Wall Survey (RIBA 5)

Project

The Ritz London

The Ritz London
Project

The Ritz
London

The Ritz London

External Wall Survey (RIBA 5)

Project

The Ritz London

10 Park Drive, Canary Wharf, London

External Wall Survey

FRAEW

Project

10 Park Drive, Canary Wharf, London

10 Park Drive, Canary Wharf, London

External Wall Survey

FRAEW

Project

10 Park Drive, Canary Wharf, London

The Ritz London
Project

10 Park Drive, Canary Wharf, London

10 Park Drive, Canary Wharf, London

External Wall Survey

FRAEW

Project

10 Park Drive, Canary Wharf, London

Get Your Fire Safety Consultation

Contact us today for expert advice and support.

Get Your Fire Safety Consultation

Contact us today for expert advice and support.

Get Your Fire Safety Consultation

Contact us today for expert advice
and support.

Get Your Fire Safety Consultation

Contact us today for expert advice and support.

Follow us

© 2024 Specialist Building Consultancy

Contact

steven@sbc-limited.com

020 8050 7677

Follow us

© 2024 Specialist Building Consultancy

Follow us

© 2024 Specialist Building Consultancy

Follow us

© 2024 Specialist Building Consultancy

Contact

steven@sbc-limited.com

020 8050 7677